FVA-Workbench 10.1.1
Bugfixes
CAD export of cylindrical gears (including modifications) applied the helix angle modification in the wrong direction. This has been corrected.
Unloaded notches can now be calculated in accordance with DIN 743. Safety factors are output as "infinite" in reports.
An error in transferring the ring gear speed from the system to the calculation of free planetary stages with a rotating ring gear has been fixed.
Mass calculations could lead to excessive memory consumption. This has been corrected.
An error in the "Local results on 3D tooth flank" diagram with asymmetric gears has been fixed.
An error in the output of tolerance values in the "K chart" diagram has been fixed.
Matlab Runtime R2022b (9.13) could not be found for plain bearing calculations with COMBROS, even if it was selected for the FVA-Workbench Installer download. This problem has been fixed.
An error that prevented the Workbench from starting if the user directory included special characters has been fixed.
Calculation of eigenvalues is not currently possible for models with FEM components. The corresponding error message has been corrected.
An error in the "Local results on 3D tooth flank" diagram with asymmetric gears has been corrected. Control of the calculation has been improved.